MDS Interoperability Mode Limitations

When a VSAN is configured for the default interoperability mode, the MDS 9000 Family of switches is limited in the following areas when interoperating with non-MDS switches:

• Interop mode only affects the specified VSAN. The MDS 9000 switch can still operate with full functionality in other non-interop mode VSANs. All switches that partake in the interoperable VSAN should have that VSAN set to interop mode, even if they do not have any end devices.

• Domain IDs are restricted to the 97 to 127 range, to accommodate McData's nominal restriction to this same range. Domain IDs can either be set up statically (the MDS 9000 switch will only accept one domain ID; if it does not get that domain ID, it isolates itself from the fabric), or preferred (if the MDS 9000 switch does not get the requested domain ID, it takes any other domain ID).

• TE ports and PortChannels cannot be used to connect an MDS 9000 switch to a non-MDS switch. Only E ports can be used to connect an MDS 9000 switch to a non-MDS switch. However, TE ports and PortChannels can still be used to connect an MDS 9000 switch to other MDS 9000 switches, even when in interop mode.

• Only the active zone set is distributed to other switches.

• In MDS SAN-OS Release 1.3(x), Fibre Channel timers can be set on a per VSAN basis. Modifying the times, however, requires the VSAN to be suspended. Prior to SAN-OS Release 1.3, modifying timers required all VSANs across the switch to be put into the suspended state.

• The MDS 9000 switch still supports the following zoning limits per switch across all VSANs:

– 2000 zones (as of SAN-OS 3.0, 8000 zones)

– 20000 aliases

– 1000 zone sets

– 20000 members

– 8000 LUN members

– 256 LUN members per zone/alias

Brocade Interoperability Mode Limitations

When interoperability mode is set, the Brocade switch has the following limitations:

• All Brocade switches should be in Fabric OS 2.4 or later.

• Interop mode affects the entire switch. All switches in the fabric must have interop mode enabled.

Msplmgmtdeactivate must be run prior to connecting the Brocade switch to either an MDS 9000 switch or a McData switch. This command uses Brocade proprietary frames to exchange platform information. The MDS 9000 switch and McData switches do not understand these proprietary frames, and rejection of these frames causes the common E ports to become isolated.

• Enabling interoperability mode is a disruptive process to the entire switch. It requires the switch to be rebooted.

• If there are no zones defined in the effective configuration, the default behavior of the fabric is to allow no traffic to flow. If a device is not in a zone, it is isolated from other devices.

• Zoning can only be done with pWWNs. You cannot zone by port numbers or nWWNs.

• To manage the fabric from a Brocade switch, all Brocade switches must be interconnected. This interconnection facilitates the forwarding of the inactive zone configuration.

Domain IDs are restricted to the 97 to 127 range to accommodate McData's nominal restriction to this same range.

• Brocade WebTools will show a McData switch or an MDS 9000 switch as an anonymous switch. Only a zoning configuration of the McData switch or the MDS 9000 switch is possible.

• Private loop targets will automatically be registered in the fabric using translative mode.

• Fabric watch is restricted to Brocade switches only.

• The full zone set (configuration) is distributed to all switches in the fabric. However, the full zone set is distributed in a proprietary format, which only Brocade switches accept. Other vendors reject these frames, and accept only the active zone set (configuration).

• The following services are not supported:

– The Alias Server


What are the CLARiiON SAN fan-in and fan-out configuration rules?"

Fan-In Rule: A server can be zoned to a maximum of four storage systems.

Fan-Out Rule:

  • For FC5300 with Access Logix software - 1 - 4 servers (eight initiators) to 1 storage system.
  • For FC4500 with Access Logix - 15 servers to 1 storage system; each server with a maximum of one (single) path to an SP.
  • For FC4700 with Base or Access Logix software 8.42.xx or higher - 32 initiators per SP port for a maximum of 128 initiators per FC4700. Each port on each SP supports 32 initiators. Ports 0 and 1 on each SP in a FC4700 handles server connections. Port 1 on each SP in a FC4700 with MirrorView also handles remote mirror connections. In a remote mirror configuration, each path between SP A port 1 on one storage system and SP A port 1 on another storage system counts as one initiator for each port 1. Likewise, each path between SP B port 1 on one storage system and SP B port 1 on another storage system counts as one initiator for each port 1.
  • For FC4700 with Base or Access Logix software 8.41.xx or lower - 15 servers to 1 storage system; each server with a maximum of one (single) path to an SP.
  • For CX200 - 15 initiators per SP, each with a maximum of one (single) path to an SP; maximum of 15 servers.
  • Fan-Out for CX300 - 64 initiators per SP for a maximum of 128 initiators per storage system.
  • For CX400 - 32 initiators per SP port for a maximum of 128 initiators per CX400. Each port on each SP supports 32 initiators. Ports 0 and 1 on each SP in a CX400 handles server connections. Port 1 on each SP in a CX400 with MirrorView also handles remote mirror connections. In a remote mirror configuration, each path between SP A port 1 on one storage system and SP A port 1 on another storage system counts as one initiator for each port 1. Likewise, each path between SP B port 1 on one storage system and SP B port 1 on another storage system counts as one initiator for each port 1.
  • Fan-Out CX500 - 128 initiators per SP and maximum of 256 initiators per CX500 available for server connections. Ports 0 and 1 on each SP handle server connections. Port 1 on each SP in a CX500 with MirrorView/A or MirrorView/S enabled also handles remote mirror connections. Each path used in a MirrorView or SAN Copy relationship between two storage system counts as an initiator for both storage systems.
  • For CX600 - 32 initiators per SP port and maximum of 256 initiators per CX600 available for server connections. Ports 0, 1, 2, and 3 on each SP in any CX600 handle server connections. Port 3 on each SP in a CX600 with MirrorView also handles remote mirror connections. In a remote mirror configuration, each path between SP-A port 3 on one storage system and SP-A port 3 on another storage system counts as one initiator for each port 3. Likewise, each path between SP-B port 3 on one storage system and SP-B port 3 on another storage system counts as one initiator for each port 3.
  • Fan-Out CX700 - 256 initiators per SP and maximum of 512 initiators per CX700 available for server connections. Ports 0, 1, 2, and 3 on each SP in any CX700 handle server connections. Port 3 on each SP in a CX700 with MirrorView/A or MirrorView/S enabled also handles remote mirror connections. Each path used in a MirrorView or SAN Copy relationship between two storage system counts as an initiator for both storage systems
  • An initiator is any device with access to an SP port. Each port on each SP supports 32 initiators. Check with your support provider to confirm that the above rules are still in effect.