Lets first disuss what is Powerpath software. If you are familiar with EMC product and then definitelly will be using EMC Powerpath software.
Those who are new to storage world, it will interesting to know about this product as there are only few software in this category like DMP,PVLINK, LVM etc from other vendor. This sofware is one of the most robust compare to other, thats reason EMC generationg more revenue out of this Product.... .

EMC PowerPath software is Host/Server based failover software, what is that mean failover. failover can be anything like server,HBA,Fabric etc. If you have fully licenced package in your enviornment then you will have all capability. Most important not least this software got good feature like dynamic IO Loading and Automatic Failure detection which is missing in other product. Basically in short we can define that EMC PowerPath provides you to have HA configuration. EMC Powerpath slogan is like "set it and forget".

EMC PowerPath features a driver residing on the host above HBA Device Layer. This transparent componenet allows PowerPath to create Virtual(power) devices that provide failure resistant and load balanced paths to storage systems. An application needs only to reference a virt ual device while Powerpath manages path allocation to storage system.
With PowerPath, the route between server and storage system can assume a complex path. One powerpath device include as many as 32 physical I/O paths ( 16 for Clariion), with each path designated to the operating system by different name.
In most cases, the application must be reconfigured to use pseudo devices, otherwise PowerPath load balancing and path failover functionality will not be available.




The following describe whether application need to be reconfigure to use pseudo devices.
1) Windows Plateform :- No. ( Application not require to reconfigured to use Pseudo Devices )
2) AIX :- NO- For LVM, Yes, if applicaiton do not use LVM
3) HP-UX - NO
4) Solaris :- Yes, Incluing filesystem mounting tables and volume managers.
5) Linux :- Same as Solaris
if you attach new LUN to Host, powerpath automatically detect that LUN if you have exposed correctly and create device name like emcpower1c, emcpower2c etc, even when you type command on CLI like
#powermt display dev=all;
you will be able to device entry like emcpowerN.....
Hope this will help you to understand why powerpath uses pseudo devices?

DMP With CLARiiON:-

CLARiiON arrays are active-passive devices that allow only one path at a time to be used for I/O. The path that is used for I/O is called the active or primary path. An alternate path (or secondary path) is configured for use in the event that the primary path fails. If the primary path to the array is lost, DMP automatically routes I/O over the secondary path or other available primary paths.

For active/passive disk arrays, VxVM uses the available primary path as long as it is accessible. DMP shifts I/O to the secondary path only when the primary path fails. This is called "failover" or "standby" mode of operation for I/O. To avoid the continuous transfer of ownership of LUNs from one controller to another, which results in a severe slowdown of I/O, do not access any LUN on other than the primary path (which could be any of four available paths on a FC4700 and CX-Series arrays).

Note: DMP does not perform load balancing across paths for active-passive disk arrays.

DMP failover functionality is supported and should attempt to limit any scripts or processes from using the passive paths to the CLARiiON array. This will prevent DMP from causing unwanted LUN trespasses.

To view potential trespasses, look at the ktrace (kt_std) information from SPcollect, messages similar the following can be seen happening with regularity.

09:07:31.995 412 820f6440 LUSM Enter LU 34 state=LU_SHUTDOWN_TRESPASS
09:07:35.970 203 820f6440 LUSM Enter LU 79 state=LU_SHUTDOWN_TRESPASS
09:07:40.028 297 820f6440 LUSM Enter LU 13 state=LU_SHUTDOWN_TRESPASS
09:07:42.840 7 820f6440 LUSM Enter LU 57 state=LU_SHUTDOWN_TRESPASS

The "Enter LU ##" is the decimal array LUN number one would see in the Navisphere Manager browser. When the messages occur, there will be no 606 trespass messages in the SP event logs. This is an indication that thetrespasses are the 'masked out' DMP trespass messages. Executing I/Os to the /dev/dsk device entry will cause this to happen.

Using the SPcollect SP_navi_getall.txt file, check the storagegroup listing to find out which hosts these LUNs belong to. Then obtain an EMCGrab/EMCReport from the affected hosts and you will need to look for a host-based process that could potentially be sending I/O down the 'passive' path. Those I/Os can be caused by performance scripts, format or devfsadm commands being run or even host monitoring software that polls all device paths.
One workaround is to install and configure EMC PowerPath. PowerPath disables the auto trespass mode and is designed to handle I/O requests properly so that the passive path is not used unless required. This will require changing the host registration parameter "failover mode" to a '1'. This failover mode is termed an "explicit mode" and it will resolve the type of trespass issues noted above.

Setting Failover Values for Initiators Connected to a Specific Storage System:

Navisphere Manager lets you edit or add storage system failover values for any or all of the HBA initiators that are connected to a storage system and displayed in the Connectivity Status dialog box for that storage system.

1. In the Enterprise Storage dialog box, navigate to the icon for the storage system whose failover properties you want to add or edit.
2. Right-click the storage system icon, and click Connectivity Status.
3. In the Connectivity Status dialog box, click Group Edit to open the Group Edit Initiators dialog box.
4. Select the initiators whose New Initiator Information values you want to add or change, and then add or edit the values in Initiator Type, ArrayCommPath and Failover Mode.
5. Click OK to save the settings and close the dialog box.
Navisphere updates the initiator records for the selected initiators, and registers any unregistered initiators.

Background Verify and Trespassing

Background Verify must be run by the SP that currently owns the LUN. Trespassing is a means of transferring current ownership of a LUN from one SP to the other. Therefore, aborting a Background Verify is part of the trespass operation – it is a necessary step.