In order to use the control functions of Solutions Enabler, you must create device groups and add/associate Symmetrix devices with the group. The following example shows how to create a device group, add a standard device to it and associate two BCV devices to the group.
The following commands will create a device group using the default type (regular). Next we will add a device to the device group and assign it a logical name. Then we associate two BCV devices with the device group so we can switch back and forth with the BCV devices.

symdg create mygroupsymld -g mygroup add dev 000 STD000
symbcv -g mygroup associate dev 110 BCV000
symbcv -g mygroup associate dev 111 BCV001

NOTE: At this point you have only added/associated devices with a device group. These actions do not in any way describe which devices should actually be paired. This may be confusing as the documentation is not very explicit. The fact is that the symmetrix may already have BCV pair information about these devices depending on how they were used in the past.
Now issue the commands to define the STD/BCV pair and actually synchronize the pair with a full establish.

symmir -g mygroup -full establish STD000 BCV dev 110
or
symmir -g mygroup -full establish STD000 BCV ld BCV000

This explicit definition of the STD device and the particular BCV device will cause any existing pair information to be disregarded and will use this new information to create a pair. This is

comparable to the older TimeFinder Command Line Interface "bcv -f filename" where the file "filename" consisted on one line entries pairing STD devices with BCV devices. And finally, split this TimeFinder pair and synchronize the STD device with a different BCV device.
symmir -g mygroup split
symmir -g mygroup -full establish STD000 BCV dev 111

Another method to establish pairs, using the "-exact" option [Available in V3.2-73-06 and higher]The -full -exact options on the symmir command instructs SYMCLI to define the STD/BCV pairs in the same order they were entered into the device group.

symdg create mygroupsymld -g mygroup add dev 000 STD000
symld -g mygroup add dev 001 STD001
symbcv -g mygroup associate dev 110 BCV000
symbcv -g mygroup associate dev 111 BCV001
symmir -g mygroup -full -exact establish

This will pair the first STD device (STD000) with the first BCV (BCV000) entered into the device group, and pair the second STD device (STD001) with the second BCV (BCV001) entered into the device group.

When running inq or syminq, you'll see a column titled Ser Num. This column has quite a bit of information hiding in it.

An example syminq output is below. Your output will differ slightly as I'm creating a table from a book to show this; I don't currently have access to a system where I can get the actual output just yet.

Device
Product Device
------------------------ ---------- ---------------------- ----------------------
Name Type Vendor ID Rev Ser Num Cap(KB)
---------------- ----- -------- --------- ------- --------- --------
/dev/dsk/c1t0d0
EMC SYMMETRIX 5265 73009150 459840
/dev/dsk/c1t4d0 BCV EMC SYMMETRIX 5265 73010150 459840
/dev/dsk/c1t5d0 GK EMC SYMMETRIX 5265 73019150 2880
/dev/dsk/c2t6d0 GK EMC SYMMETRIX 5265 7301A281 2880

Using the first and last serial numbers as examples, the serial number is broken out as follows:

73 Last two digits of the Symmetrix serial number
009 Symmetrix device number
15 Symmetrix director number. If <= 16, using the A processor
0 Port number on the director


73 Last two digits of the Symmetrix serial number
01A Symmetrix device number
28 Symmetrix director number. If > 16, using the B proccessor on board: (${brd}-16).
0 Port number on the director

So, the first example, device 009 is mapped to director 15, processor A, port 0 while the second example has device 01A mapped to director 12, processor B, port 0.



Even if you don't buy any of the EMC software, you can get the inq command from their web site. Understanding the serial numbers will help you get a better understanding of which ports are going to which hosts. Understanding this and documenting it will circumvent hours of rapturous cable tracings.